COOLING INTERFACE UNIT

  • EPP COVER
  • BESPOKE OPTIONS AVAILABLE
  • LOW ENERGY USAGE
  • 7 YEAR WARRANTY*

YGHP CIU DATA SHEET

YGHP Cooling Interface Unit (CIU) product family is designed to satisfy a range of costumer demands in terms of cooling. CIU provides cooling solutions for apartments, houses, and offices.

The CIU has all necessary components (e.g. valves, heat exchanger, circulation pump, expansion vessel,
pipes, fitting and connections) to deliver convenient and efficient cooling.

The CIU has 4 types based on the heat exchanger specifications. To connect the CIU with the piping system of apartments, houses, or offices, Mounting Plates With 6 Ball Valves are used. The Flushing By-pass component enables flushing and venting the system before commissioning. The CIU is covered with high quality EPP Covers.

Compact design to fit any design specification.

Latest SWEP plate heat exchanger offering exceptional performance.

3, 6, 9 and 15kW Models Available.

Stainless steel pipework to ensure high performance and longevity.
EPP thermal casing to ensure minimum heat losses and maximum heat efficiency.
COMPONENTS

Each CIU is equipped with a balance and control valve  which consists of two different parts: the control valve and the differential pressure controller. It has automatic flow limitation and built-in differential pressure control functioning over the control valve. The valve is also combined with a thermal actuator
which ensures the required flow in every unit and maintains hydronic balance in the system.

Each CIU is equipped with a plate heat exchanger to exchange heat between supply and the CIU.

In the CIU, the heat exchanger has optimized asymmetric plate geometries that combine extraordinary thermal efficiency. The heat exchanger has been selected to satisfy the requirements on the heat load and the flow rate of the system.

The Combined Thermometer/Pressure Gauge  enables the operator to observe the system temperature and pressure in a single gauge with at a single measuring point.

It has a bimetal measuring system for temperature measurement and a Bourdon tube measuring system for simultaneous pressure measurement. Both values are measured and displayed by a single gauge. A self-closing mounting valve enables the gauge to be replaced without the need to drain the system.

All YGHP cooling interface units come equipped with state of the art thermal casing, made from EPP or Expanded Polypropylene.

This ensure that the unit is reaching its maximum thermal potential and reducing heat-loss to a minimum.

The CIU is equipped with an Expansion Vessel to maintain constant pressure in the system.

The Expansion Vessel is made from rubber diaphragm fixed membrane and according to the standards established by PED 2014/68/UE and DIN EN 13831 regulations.

The Safety Valve serves as a fail-safe to protect against overpressure in the CIU. When the system pressure of the CIU exceeds 2.5 bar (factory adjusted opening pressure), it automatically releases
water from the draining outlet.

The system pressure of the CIU can be monitored by the Combined Thermometer/Pressure Gauge.

The safety valve is made from brass and according to the standards established by DIN 4751-3 and EN 12828 regulations.

To connect the CIU and the piping system of apartment, mounting plates are used. These plates have 8 ball valves and a flushing by-pass.

Each secured on a galvanized steel plate, ball valves are connected with G ¾” male thread connections.

Flushing by-pass enables the flushing and venting of the system before commissioning the CIU.

1. Combined Temperature and Pressure Gauge 6. Ball Valves
2. Safety Valve 7. EPP Thermal Cover
3. Single SWEP Brazed Plate Heat Exchanger 8. WILO Pump
4. Electronically Controlled Circulation Pump 9. Stainless Steel Pipework
5. Balance and Control Valve 10. Expansion Vessel (Located Behind)

COOLING INTERFACE UNIT

EPP COVER

HEAT PUMP READY

LOW ENERGY USAGE

7 YEAR WARRANTY

YGHP CIU DATA SHEET

YGHP Cooling Interface Unit (CIU) product family is designed to satisfy a range of costumer demands in terms of cooling. CIU provides cooling solutions for apartments, houses, and offices.

The CIU has all necessary components (e.g. valves, heat exchanger, circulation pump, expansion vessel,
pipes, fitting and connections) to deliver convenient and efficient cooling.

The CIU has 4 types based on the heat exchanger specifications. To connect the CIU with the piping system of apartments, houses, or offices, Mounting Plates With 6 Ball Valves are used. The Flushing By-pass component enables flushing and venting the system before commissioning. The CIU is covered with high quality EPP Covers.

Compact design to fit any design specification.
Latest SWEP plate heat exchanger offering exceptional performance.

3, 6, 9 and 15kW Models Available.

Stainless steel pipework to ensure high performance and longevity.

EPP thermal casing to ensure minimum heat losses and maximum heat efficiency.

COMPONENTS

Each CIU is equipped with a balance and control valve  which consists of two different parts: the control valve and the differential pressure controller. It has automatic flow limitation and built-in differential pressure control functioning over the control valve. The valve is also combined with a thermal actuator
which ensures the required flow in every unit and maintains hydronic balance in the system.

Each CIU is equipped with a plate heat exchanger to exchange heat between supply and the CIU.

In the CIU, the heat exchanger has optimized asymmetric plate geometries that combine extraordinary thermal efficiency. The heat exchanger has been selected to satisfy the requirements on the heat load and the flow rate of the system.

The Combined Thermometer/Pressure Gauge  enables the operator to observe the system temperature and pressure in a single gauge with at a single measuring point.

It has a bimetal measuring system for temperature measurement and a Bourdon tube measuring system for simultaneous pressure measurement. Both values are measured and displayed by a single gauge. A self-closing mounting valve enables the gauge to be replaced without the need to drain the system.

All YGHP cooling interface units come equipped with state of the art thermal casing, made from EPP or Expanded Polypropylene.

This ensure that the unit is reaching its maximum thermal potential and reducing heat-loss to a minimum.

The CIU is equipped with an Expansion Vessel to maintain constant pressure in the system.

The Expansion Vessel is made from rubber diaphragm fixed membrane and according to the standards established by PED 2014/68/UE and DIN EN 13831 regulations.

The Safety Valve serves as a fail-safe to protect against overpressure in the CIU. When the system pressure of the CIU exceeds 2.5 bar (factory adjusted opening pressure), it automatically releases
water from the draining outlet.

The system pressure of the CIU can be monitored by the Combined Thermometer/Pressure Gauge.

The safety valve is made from brass and according to the standards established by DIN 4751-3 and EN 12828 regulations.

To connect the HIU and the piping system of apartment, mounting plates are used. These plates have 8 ball valves and a flushing by-pass.

Each secured on a galvanized steel plate, ball valves are connected with G ¾” male thread connections.

Flushing by-pass enables the flushing and venting of the system before commissioning the HIU.

1. Combined Temperature and Pressure Gauge 6. Ball Valves
2. Safety Valve 7. EPP Thermal Cover
3. Single SWEP Brazed Plate Heat Exchanger 8. WILO Pump
4. Electronically Controlled Circulation Pump 9. Stainless Steel Pipework
5. Balance and Control Valve 10. Expansion Vessel (Located Behind)